Cable management on an exhibition stand: the short answer
The cleanest way to manage cables on an exhibition stand is to run them inside the floor. The Stand-On exhibition floor is a raised modular floor made of 50 × 50 cm tiles with built-in channels. You lay power, data and AV cables into the channels from above, then close the floor with cover plates. With cover plates the floor is only 30 mm high.
The result: no cables taped to the carpet, no cable bridges in the walkway and a stand that looks finished from the aisle.
Why cables on top of the floor cause problems
On many stands, cables run across the hall floor under carpet and tape. That creates bumps and trip hazards, and it makes late changes difficult: if a counter or screen moves on build-up day, the cable runs have to be redone. After the show, someone has to remove the tape and the cable residue.
A raised floor with integrated cable management solves this at the source. The cables disappear below the walking surface, and you can still reach them when something changes.
How cable management in the Stand-On floor works
The base tiles have plenty of channels to insert cables. Because you lay the cables in from the top, you do not have to lift the whole floor to add or relocate a cable. The channels can also be used as strain relief.
Cables with a cross-section of 10 mm or less fit directly into the channels. Larger cables can also be stored inside the floor. For stands with a lot of technology there is the Stand-On AV tile, which gives extra space beneath the floor for power cables, data cables, AV equipment, air hoses and water lines.
What fits inside the floor
According to the Stand-On specifications, the floor takes the cabling a typical stand needs:
- Power and internet cables
- CEE cables of 5 × 2.5 mm² and 5 × 6 mm², and flat cable 5G6 H07RN-F
- Wieland connectors and AV connections
- Water pipes up to 20 mm and air hoses
Plan your cable routes before build-up
Good cable management starts on the floor plan. Mark where counters, screens, lighting and power points will stand. Decide where the main feed enters the stand, usually at an edge or under a counter. Then choose where you need standard base tiles and where an AV tile gives you more room.
Edges matter too: an aluminium sloping edge with integrated LED lighting also needs power, and that cable can run inside the floor as well.
Safer for visitors and staff
Loose cables and taped carpet edges are a common trip hazard on a busy stand. When the cables run inside the floor, the walking surface stays level and visitors do not trip over raised carpet edges. Sloping edges give a smooth transition from the hall floor, and the floor is wheelchair-friendly. Anti-slip printed cover plates are available as well.
For stand builders, the same floor also means fewer last-minute fixes: when a counter moves, the cable moves with it inside the floor.
More than hidden cables
The same floor makes the whole stand easier to build. Each tile weighs 1.5 kg and connects by hand with clickers, so one person can install the floor without tools. Triangular nocks grip into each other and level the surface, and most uneven hall floors are handled by the tiles themselves.
The floor carries up to 3,600 kg/m² (900 kg per tile), is tested to fire class B1 by TÜV Rheinland and comes with a lifetime warranty on product use. You can buy it or rent it.
Frequently asked questions about exhibition stand cable management
What is the best way to hide cables on an exhibition stand?
Run them inside a raised floor. In the Stand-On floor, cables lie in channels in the 50 × 50 cm base tiles, below the cover plates, so nothing lies on top of the walking surface.
How high is the floor?
26 mm without and 30 mm with cover plates.
Which cable sizes fit in the tiles?
Cables with a cross-section of 10 mm or less fit directly into the channels. Larger cables can also be stored inside the floor, and the AV tile gives extra space.
Can I add or move cables after the floor is laid?
Yes. You lay cables into the channels from above, so you do not have to take the whole floor apart to add or relocate a cable.
What is the Stand-On AV tile?
A tile for projects with advanced cable management. It gives extra space beneath the floor for power and data cables, AV equipment, air hoses and water lines.
Can water pipes run through the floor?
Yes. Water pipes up to 20 mm and air hoses can run inside the floor.
Do I need tape to secure carpet and cables?
No. Cables lie inside the tiles and the cover plates sit on top, so tape or double-sided tape is no longer needed.
Is the floor fire safe?
The floor is tested to fire class B1 by TÜV Rheinland.
Can I rent the floor?
Yes, the floor can be bought or rented. Design your floor online or contact us for a quote.
More questions? Contact us or design your floor in the online configurator.